VICTRON ENERGY
SMARTSOLAR MPPT 150/35
SMARTSOLAR MPPT 150/35
SKU:SCC115035210
A solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, SmartSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. SmartSolar maintains battery health, extending its life.
The SmartSolar charge controller will even recharge a severely depleted battery. It can operate with a battery voltage as low as 0 Volts, provided the cells are not permanently sulphated or otherwise damaged.
Solar charge controller
A solar charger gathers energy from your solar panels and stores it in your batteries. Using the latest, fastest technology, SmartSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. SmartSolar maintains battery health, extending its life.
The SmartSolar charge controller will even recharge a severely depleted battery. It can operate with a battery voltage as low as 0 Volts, provided the cells are not permanently sulphated or otherwise damaged.
MPPT: Ultra Fast Maximum Power Point Tracking
By constantly monitoring the voltage and current output of your solar (PV) panels, MPPT technology ensures that every drop of available power is rinsed out of your panels and harvested for storage. The advantage of this is most noticeable when the sky is partially clouded, and light intensity is constantly changing.
Remote Monitoring and Control
Battery voltage | 12 / 24 / 48 V Auto Select (software tool needed to select 36 V) |
Rated charge current | 35 A |
Nominal PV power @ 12V (A) | 500 W |
Nominal PV power @ 24V (A) | 1000 W |
Nominal PV power @ 36V (A) | 1500 W |
Nominal PV power @ 48V (A) | 2000 W |
Max. PV short circuit current (B) | 40 A |
Maximum PV open circuit voltage | 145 V |
Maximum efficiency | 98 % |
Charge voltage 'absorption' | 14,4 / 28,8 / 43,2 / 57,6 V (adjustable) |
Charge voltage 'float' | 13,8 / 27,6 / 41,4 / 55,2 V (adjustable) |
Charge algorithm | multi-stage adaptive (eight pre-programmed algorithms) |
Protection | PV reverse polarity / output short circuit / over-temperature |
Operating temperature | -30 to +60°C (full rated output up to 40°C) |
Data communication port | VE.Direct |
Weight | 1,25 kg |
Dimensions (h x w x d) | 130 x 186 x 70 mm |
Data stored | Battery voltage,current and temperature, as well as load output current, PV voltage and PV current. |
Number of days trends data is stored | 46 |
(A) If more PV power is connected, the controller will limit input power.
The PV voltage must exceed Vbat + 5 V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1 V.
(B) A PV array with a higher short circuit current may damage the controller.